NTI E-ALDS Addressable Leak Detection Sensor

Rp 7.200.000
Spesialis Elektronik – NTI E-ALDS Addressable Leak Detection Sensor
  • Monitors up to 4,000 feet of E-LDDC-x Liquid Location Detection Sensor Cable.
    • Detects the specific location of liquid presence.
      • If multiple leaks are occurring at the same time, you will receive notification of the location for the leak closest to E-ALDS. Once that leak is cleared, you will receive notification of the next leak closest to the E-ALDS. This will continue until all leaks are cleared.
    • Detects if there is a break in the cable.
  • Supports up to 1,000 feet of E-4WNSC-x non-sensing cable.
  • Leak location accuracy:
    • 20 to 1,500 feet: ±(1ft + 0.5% of sensing cable length).
    • 1,500 to 4,000 feet: ±1% of sensing cable length.
  • Built-in Piezo buzzer emits loud beeps to alert personnel.
    • Output level: 70dB at 1 foot
  • Max current consumption: 13mA @ 5VDC, 18mA@12VDC
  • Powered by E-2D/5D/16D.
  • Compatible with E-2D/5D/16D.
    • Interfaces with the E-2D/5D/16D via the RJ45 sensor port
    • Extend up to 500 feet from the E-2D/5D/16D
  • M12 4-pin connector for connecting E-LDDC-x Liquid Location Detection Sensor Cable or E-4WNSC-x Non-Sensing Cable
  • Dimensions WxDxH: 3.21x2.5x1.22 in (82x64x31 mm)
  • Operating temperature: 32 to 158°F (0 to 70°C).
  • Regulatory approvals: CE, RoHS
  • Integrated mounting brackets for easy surface/wall mounting.
  • Use the included terminator at the end of the E-LDDC-x Liquid Location Detection Sensor Cable

NTI E-CLPxx-LD Self-Adhesive Clips for Liquid/Chemical Sensor Rope

Rp 321.750
Spesialis Elektronik – NTI E-CLPxx-LD Self-Adhesive Clips for Liquid/Chemical Sensor Rope
  • Use to prevent sensor rope cable from shifting after installation
  • Self-adhesive backing for easy installation
  • Recommended distance between clips
    • Cables less than 5 ft long: one clip at each end.
    • Cables more than 5 ft long: minimum 5 ft apart.
  • Material: Nylon
  • Available quantities per package: 10, 100
  • Compatible with E-LDSx-y, E-CDSx-y, E-LDx-y and E-CDx-y
 

NTI E-RTDT-140 100 Ohm Platinum RTD Transmitter

Rp 5.850.000
Spesialis Elektronik – NTI E-RTDT-140 100 Ohm Platinum RTD Transmitter
  • Use to connect 100 Ohm RTD temperature sensors to the E-2D/5D/16D.
  • Available temperature ranges:
    • E-RTDT-140: -20 to 140°F (-28 to 60°C).
    • E-RTDT-240: 30 to 240°F (-1 to 115°C).
  • Accurate to within ±0.8°F (±0.45°C).
  • Configuration: 2-wire connection
  • Sensor Element: 100Ω platinum
  • Signal Output: 4-20 mA, loop-powered
  • Requires the E-S420MA-24V and an RTD sensor probe to operate with the E-2D/5D/16D.
    • Powered by E-2D/5D/16D.
  • Single gang weather resistant enclosure.
  • Dimensions WxDxH: 2.81x4.50x2.13 in (71x114x54 mm)
  • Regulatory approvals: CE

NTI E-RTDT-1562 High-Accuracy 100 Ohm Platinum RTD Transmitter

Rp 22.050.000
Spesialis Elektronik – NTI E-RTDT-1562 High-Accuracy 100 Ohm Platinum RTD Transmitter
  • Use to connect 100 Ohm platinum RTD temperature sensors to the E-2D/5D/16D.
  • Temperature range: -328 to 1562°F (-200 to 850°C)
    • When used with the E-2D/5D/16D, the supported range is -89 to 738°F (-67 to 392°C. Call an NTI product consultant to have the range expanded on the ENVIROMUX system.
  • Accurate to within ±0.2°F (±0.1°C)
    • If the connected RTD sensor does not support this high of accuracy, the system will revert to the accuracy of the sensor.
  • Configuration: 2, 3, or 4-wire connection
  • Sensor Element: 100Ω platinum
  • Signal Output: 4-20 mA
  • Requires the E-S420MA-24V and an RTD sensor probe to operate with the E-2D/5D/16D.
  • Din rail mount housing.
  • Dimensions WxDxH: 5.08x4.09x0.89 in (129x104x23 mm)
  • Includes pre-stripped country-specific line cord with tinned strands.
  • Operating temperature: 32 to 131°F (0 to 55°C).
  • Storage temperature: -40 to 185°F (-40 to 85°C).

NTI E-S420MA-24V 4-20mA Sensor Converter

Rp 5.850.000
Spesialis Elektronik – NTI E-S420MA-24V 4-20mA Sensor Converter
  • External RJ45 device monitors up to two 4-20 mA analog sensors
  • Supports ISA Type 2, ISA Type 3, and ISA Type 4 sensors
  • Provides 24VDC, 25mA for each sensor
  • Connector: Screw Terminal, 8-position.
  • Supports CAT5/5e/6 cable up to 1,000 ft. (305 m)
  • Includes Mounting Hardware
  • Dimensions (WxDxH): 4.15x2.3x1.2" (105x58x30 mm)
  • Powered by E-2D/5D/16D.
  • Compatible with E-2D/5D/16D.
  • Regulatory approvals: RoHS.
  • Compatible with E-FSC Fiber Converter/Extender.
    • Use to extend sensor up to 1.2 miles (2 km) from the ENVIROMUX unit.
  • Requires the E-RTDT-140/240/1562 and E-S420MA-24V to operate with the E-2D/5D/16D.
    • E-RTDT-140 supports temperatures -20 to 140°F (-28 to 60°C).
    • E-RTDT-240 supports temperatures 30 to 240°F (-1 to 115°C).
    • E-RTDT-1562 supports temperatures -328 to 1562°F (-200 to 855°C).

Panel Alarm Deteksi Kecepatan Angin Sensor External 1 Titik

Spesialis Elektronik – Panel Alarm Deteksi Kecepatan Angin Sensor External 1 Titik

Panel Alarm Deteksi Suara Noise Sensor External 1 Titik

Spesialis Elektronik – Panel Alarm Deteksi Suara Noise Sensor External 1 Titik