Data center monitoring system (DCMS) atau environment monitoring system (EMS) adalah solusi berbasis teknologi yang dirancang untuk mengumpulkan, menganalisis, dan menafsirkan data dari berbagai sensor.
NTI E-CDSx-y Legacy Chemical Detection Sensor
Rp 3.532.000
Dinilai 0 dari 5
Spesialis Elektronik – NTI E-CDSx-y Legacy Chemical Detection Sensor
- For detecting the presence of chemical liquid.
- Reliably senses acids, bases, and other conductive liquids.
- Detects liquid depth >0.1" (2.5 mm).
- Minimum puddle: 0.6" (15 mm) diameter.
- Chemical resistant – cable functions normally after seven-day exposure to:
- Fresh deionized water
- Tap water
- Sulfuric acid, H2SO4 (98%)
- Sulfuric acid, H2SO4 (50%)
- Hydrochloric acid, HCl (37%)
- Sodium hydroxide, NaOH (10%)
- Aqua regia, HNO3+3 HCl
- Ethylene glycol, C2H6O2 (60% in DI water)
- Features a non-conductive polymer mesh that prevents false alarms caused by dirt/dust buildup, metal contact, or pressure on the rope.
- Voltage and current:
- Open Circuit: 5VDC max @ 1µA.
- Closed circuit: <300mV @ 10.7mA.
- RJ45 connector.
- Supports CAT5/5e/6 cable up to 1,000 ft. (305 m)
- Available chemical sensor cable (x) lengths: 1/10/50/100 feet.
- 100% waterproof
- Contact an NTI product consultant for cable lengths over 100 feet (30 meters) - supports up to 1,000 feet (305 meters).
- Available 2-wire plenum cable (y) lengths: 5/10/20/50/100 feet.
- Plenum rating: CL2P (UL)
- Diameter: 0.25 in (6.35mm)
- Contact an NTI product consultant for cable lengths over 100 feet (30 meters) – supports up to 1,000 feet (305 meters).
- Powered by E-SEMS-16U or SERIMUX-S-x.
- Requires the E-SEMS-16U or SERIMUX-S-x to operate.
- " Use self-adhesive clips (E-CLPxx-LD) to prevent sensor rope cable from shifting after installation.
NTI E-CDx-y Chemical Detection Sensor
Rp 2.542.500
Dinilai 0 dari 5
Spesialis Elektronik – NTI E-CDx-y Chemical Detection Sensor
- For detecting the presence of chemical liquid.
- Reliably senses acids, bases, and other conductive liquids.
- Detects liquid depth >0.1" (2.5 mm).
- Minimum puddle: 0.6" (15 mm) diameter.
- Chemical resistant – cable functions normally after seven-day exposure to:
- Fresh deionized water
- Tap water
- Sulfuric acid, H2SO4 (98%)
- Sulfuric acid, H2SO4 (50%)
- Hydrochloric acid, HCl (37%)
- Sodium hydroxide, NaOH (10%)
- Aqua regia, HNO3+3 HCl
- Ethylene glycol, C2H6O2 (60% in DI water)
- Features a non-conductive polymer mesh that prevents false alarms caused by dirt/dust buildup, metal contact, or pressure on the rope.
- Voltage and current:
- Open Circuit: 5VDC max @ 1µA.
- Closed circuit: <300mV @ 10.7mA.
- Available chemical sensor cable (x) lengths: 1/10/50/100 feet.
- 100% waterproof
- Contact an NTI product consultant for cable lengths over 100 feet (30 meters) - supports up to 1,000 feet (305 meters).
- Available 2-wire plenum cable (y) lengths: 5/10/20/50/100 feet.
- Plenum rating: CL2P (UL)
- Diameter: 0.25 in (6.35mm)
- Contact an NTI product consultant for cable lengths over 100 feet (30 meters) – supports up to 1,000 feet (305 meters).
- Regulatory approvals: CE, RoHS
- Use self-adhesive clips (E-CLPxx-LD) to prevent sensor rope cable from shifting after installation.
NTI E-CMD Carbon Monoxide Detector, CO
Rp 13.050.000
Dinilai 0 dari 5
- Continuous air monitoring.
- Pre-set alarm points alert at:
- 70 ppm after 60 to 240 minutes
- 150 ppm after 10 to 50 minutes
- 400 ppm after 4 to 15 minutes
- Flush or surface mount.
- Test functionality of electrochemical CO sensing cell.
- Connect to RJ45 or digital input sensor ports.
- Screw terminal
- To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
- Maximum cable length: 1000 ft (305m)
- LED indicators for operation status and system test.
- Current consumption: 40mA @ 12VDC.
- Powered by E-2D/5D/16D.
- Regulatory approvals: UL
NTI E-CO2-LC Carbon Dioxide Sensor, CO2
Rp 12.375.000
Dinilai 0 dari 5
- Measures CO2 in a range of 0 to 5,000 ppm.
- Accuracy: ±(3% of reading + 50ppm) at 77°F (25°C)
- Sensing element: Single Beam Non-Dispersive Infrared (NDIR)
- 0 to 5 VDC output.
- Includes 12V/1A power supply.
- Current consumption: 60mA @ 12VDC.
- Weatherproof enclosure.
- IP65-rated water and dust protection.
- Operating temperature: 14 to 122°F (-10 to 50°C).
- Operating relative humidity: 0 to 80% non-condensing RH.
- Regulatory approvals: CE
- Requires the E-S5VDC sensor converter to operate with E-2D/5D/16D.
- E-S5VDC maximum cable length: 1000 ft (305 m).
- E-S5VDC powered by E-2D/5D/16D.
NTI E-H2S Hydrogen Sulfide Detector
Rp 54.450.000
Dinilai 0 dari 5
- Use to monitor the presence of Hydrogen Sulfide from failed UPS (uninterrupted power supply) lead acid batteries, in paper mills, refineries, waste disposable facilities, etc.
- Measures H2S in a range of 0 to 50 ppm.
- 5A SPDT fan relay controls exhaust fans, valves, or louvers.
- Alerts are based solely on the measured H2S levels reported by the E-H2S.
- Mounts on a 4x4" electric box.
- Dimensions WxDxH (in): 4.5x4x2.13 (114x102x54 mm).
- Operating temperature: 0 to 125°F (-18 to 52°C).
- Operating and storage relative humidity: 10 to 90% non-condensing RH.
- Power consumption: 3W.
- Requires the E-S420MA-24V to operate.
- Maximum cable length: 500 ft (152 m).
- Powered by E-2D/5D/16D.
- Compatible with the E-2D/5D/16D.
- Regulatory approvals: ETL, UL.
NTI E-H2S-LC Low-Cost Hydrogen Sulfide Detector
Rp 10.575.000
Dinilai 0 dari 5
- Measures H2S in a range of 0 to 100 ppm.
- Accuracy: ±2ppm or ±10%
- Weatherproof enclosure.
- IP65-rated water and dust protection.
- Dimensions WxDxH (in): 4.33x1.73x3.35 (110x44x85mm)
- Operating temperature: -4 to 122°F (-20 to 50°C).
- Operating relative humidity: 15 to 90% non-condensing RH.
- Requires the E-S5VDC sensor converter to operate with E-2D/5D/16D.
- E-S5VDC maximum cable length: 1000 ft (305 m).
- E-S5VDC powered by E-2D/5D/16D.
- 0 to 5 VDC output.
- Powered by E-S5VDC sensor converter.
- Current consumption: 20mA @ 12VDC.
- Regulatory approvals: CE