Data center monitoring system (DCMS) atau environment monitoring system (EMS) adalah solusi berbasis teknologi yang dirancang untuk mengumpulkan, menganalisis, dan menafsirkan data dari berbagai sensor.
Didactum 14017 Smoke Detector
Rp 4.050.324
Dinilai 0 dari 5
Didactum 14043 Smoke Detector With Relay Output
Rp 6.464.802
Dinilai 0 dari 5
Didactum 14045 Multi Sensor Fire Detector
Rp 6.286.962
Dinilai 0 dari 5
Didactum 14046 Thermal Fire Detector
Rp 6.287.226
Dinilai 0 dari 5
Didactum`s thermal detector has been specially developed for the early detection of fire. This thermal fire detector comes in all applications where, because of high dust concentration, high air flow or high humidity (condensation), a use of conventional optical smoke detectors do not seem sensible.
NTI E-SDS Smoke Detector with Built-In Fixed-Temperature 135°F (57°C) Heat Sensor
Rp 2.790.000
Dinilai 0 dari 5
- For warning of smoke.
- Photoelectric smoke detector.
- Smoke sensitivity: 0.98-2.4%/ft.
- Built-in 135° F (57° C) thermal heat sensor.
- Includes mounting hardware.
- Connect to RJ45 or digital input sensor ports.
- Supports CAT5/5e/6 UTP or STP cables.
- Screw terminal
- To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
- Operating temperature: 14 to 122°F (-10 to 50°C).
- Maximum cable length: 1,000 ft (305 m)
- Current consumption: 30mA @ 12VDC.
- Powered by E-2D/5D/16D.
- Regulatory approvals: UL, RoHS
NTI E-SDS-120V Smoke Detection Sensor – 120VAC Wire-In with Battery Backup
Rp 1.530.000
Dinilai 0 dari 5
- For warning of smoke and invisible fire particles.
- Ionization smoke detector.
- Applications from 40°F to 100°F (4°C to 38°C).
- Front loading battery door.
- 9V battery backup (included) in case of power failure.
- Battery run down protection.
- One button design for easy testing and HUSH mode activation control.
- LED indicates four modes of operation: standby condition, alarm condition, alarm memory and hush mode.
- Hush mode: silences false alarms for 8 minutes, or low battery warning for 13 hours.
- Voltage supply: 120VAC.
- Pre-stripped wiring harness with tinned strands
- Audio alarm: 85dB at 10ft.
- Dimensions: 5" diameter x 1.75" depth.
- Dust cover prevents false alarms.
- Tamper resist feature.
- Links with up to 24 devices.
- Max distance between first and last device: 1000ft (305m).
- Alarm memory indicates initiating alarm in interconnected systems.
- Use compatible relay (E-RLY-SDS120V) for connection to the ENVIROMUX system or other auxiliary warning devices such as external sirens or stairwell lighting.
- E-RLY-SDS120V includes normally open and normally closed contacts.
- Contact ratings: 10A at 120VAC, 5A at 30VDC.
- Regulatory approvals: UL.
NTI E-SDS-CELC-V2 Low-Cost Smoke Detection Sensor – CE Approved
Rp 1.350.000
Dinilai 0 dari 5
- For warning of smoke.
- Photoelectric smoke detector.
- Smoke sensitivity: 0.5 dB/m ±0.1 dB/m.
- Selectable latching feature.
- Configure the sensor to auto-reset after an alarm trigger, or require a power cycle to unlatch the trigger.
- Compatible with E-2D/5D/16D.
- Interfaces with the E-2D/5D/16D via the digital input sensor ports.
- Screw terminal:
- To connect to the digital inputs use a 22 AWG 2-wire cable. Connect the other end to the sensor screw terminal.
- Operating temperature: 14 to 122°F (-10 to 50°C).
- Maximum cable length: 1,000 ft (305 m).
- Current
- Standby: 100μA
- Alarm: 30 to 35mA
- Powered by E-2D/5D/16D.
- Regulatory approvals: CE, RoHS.
NTI E-SDS-TAA-V2 Smoke Detector with Built-In Fixed-Temperature 135°F (57°C) Heat Sensor
Rp 5.400.000
Dinilai 0 dari 5
- For warning of smoke.
- Photoelectric smoke detector.
- Built-in 135° F (57° C) thermal heat sensor.
- Connect to RJ45 or digital input sensor ports.
- Supports CAT5/5e/6 UTP or STP cables.
- Voltage Supply: 8.5 to 35 VDC
- Max Current Consumption:
- 50uA max standby current @12VDC
- 20mA max alarm current @12VDC
- Alarm Output: Relay (NO)
- Screw terminal
- To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
- Maximum cable length: 1,000 ft (305 m)
- Powered by E-2D/5D/16D.
- Regulatory approvals: UL
- TAA compliant